beautypg.com

3 tfa5n – IAI America RCS2-TFA5N User Manual

Page 28

background image

6. Installation

22

6.1.3 TFA5N

This actuator has tapped holes for mounting so it can be fixed from the rear side.

Also, there is a reamed hole and a long hole for positioning pins.

(Note) When installing the unit in the horizontally oriented wall mount, put the connector cover of the cable up.

(Note) There is Nylok applied to the tapped holes on the unit. Remove the Nylok when installing the unit.

Tightening torque

Top side of table

tap size and

maximum

screw-in depth

Bolts to be used Bolt bearing surface is

steel

Bolt bearing surface is

aluminum

Top side of table

long hole

Top side of table

reamed hole

(mm)

M5 depth 7.5

M5

2.7 Nxm (0.27 kgfxm)

2.7 Nxm (0.27 kgfxm)

A: 5 B: 6 depth 5

I

5 depth 5

Tightening screws

x

For the male threads for installing the base, use hexagonal socket head bolts.

x

Use of high-tension bolts meeting at least ISO-10.9 is recommended.

x

The thread engagement length from 6.5 mm or more to 7.5 mm or less.

Caution: The tapped holes are through holes. Never use a screw longer than the effective screw

length. Internal mechanisms and electric components may be damaged.

Long hole

A

B

77

9

50

15

5

0

+ 0.030

6

40

46.5

33

37

4.5

3-M5

6.5

6.5

9

depth 10

depth 5

Long hole

4-M5

Tapped hole

depth 7.5

0

0.03

depth 5

φ5

Reamed hole

+

This manual is related to the following products: