beautypg.com

Notes on operation, 1 placing a load on the actuator – IAI America RCS2-TFA5N User Manual

Page 40

background image

8. Notes on Operation

34

8. Notes on Operation

8.1

Placing a Load on the Actuator

x

Do not exceed the load ratings given in the specification table below.

Be careful not to exceed the load moment, extension load length and maximum loading capacity for the table.

(Refer to table below.)

x

Allowable load moment

Unit: Nxm (kgfxm)

Ma

Mb

Mc

TCA5N

15 (1.5)

15 (1.5)

7.1 (0.72)

TWA5N

15 (1.5)

15 (1.5)

25.5 (2.60)

TFA5N

15 (1.5)

15 (1.5)

7.1 (0.72)

(Note) Multiply the values above by 5/3 for the moment generated in acceleration and deceleration.

Make sure the Moment generated by gravity + 5/3 × Moment by acceleration ” Dynamic allowable

moment.

TCA5N

TWA5N

Mb

Ma

Mc

Mb

Ma

Mc

This manual is related to the following products: