IAI America RCS2-TFA5N User Manual
Page 31

6. Installation
25
6.2.2 TWA5N
x
Please attach the load to the device using the tapped holes in the front plate of the table type.
x
There are also tapped holes and reamed holes in the top surface of the table. Please use these to attach the
load.
x
There is one reamed hole on the slider in the top surface of the table, so if you need to be able to secure and
detach the load multiple times, please use this hole. Also, if you require precision in your attachment, such as
a right angle, use the reamed hole to make fine adjustments.
x
Follow the table below for the attachment screws and the tightening torque.
Tightening torque
Top side of table
tap size and
maximum
screw-in depth
Bolts to be used Bolt bearing surface is
steel
Bolt bearing surface is
aluminum
Top side of table
long hole
Top side of table
reamed hole
(mm)
M5 depth 8
M5
2.7 Nxm (0.27 kgfxm)
2.7 Nxm (0.27 kgfxm)
A: 5 B: 6 depth 5
I
5 depth 5
Tightening screws
x
For the male threads, use hexagonal socket head bolts.
x
Use of high-tension bolts meeting at least ISO-10.9 is recommended.
x
The thread engagement length from 6.5 mm or more.
x
Mount a work part by holding the table as shown in the figure. If you hold only the main body and tighten the
work part, excessive moment is applied to the guide area and play may be generated.
* Pay attention to the thread length, because the threaded holes on the front table are through holes.
Main body
Long hole
A
B