beautypg.com

Alarm (output) installation, Dvr installation, Sensor installation – SecurityMan NDVR-04 User Manual

Page 8

background image

8

Alarm (output) Installation

Note: Each sensor corresponds to each camera channel, for example, alarm input #1 will

correspond to channel #1 and so on.

DVR Installation

This unit contains 4 sensor inputs in which each sensor corresponds to the 4 channels. The sensor

installation procedures are as follow. There are two simple step in installing the sensors.

connecting the sensor signal line: connect the sensor signal line to DVR. The sensor signal terminal

is located on the rear panel of the DVR.

Then Connect the sensor jack to the sensor, and plug in the adaptor to an electrical outlet to power up sensor.

Sensor Installation

IN1

IN2

IN3

IN4

Alarm (output)

The unit provides 1 internal switch to sound the alarm when the sensor is activated. The switch is open at normal

state a wiring diagram as shown below. When the alarm is activated, the switch is closed so that the alarm gets the

power. The circuitry is shown as in the below figure. There are two simple steps to install the alarm.

a) Prepare the power supply for the alarm by connecting the power adapter from the camera to the power

outlet.

b) Connect the alarm power line to the alarm output terminal located on the back of the DVR as shown below.

Alarm

AC/DC adaptor

Power outlet

Signal Line

Power

NOTICE: Sensor input is RECOGNIZED as LOW when alarm

signal is on the same level with GND, and it is recognized as

HIGH when alarm signal is Floating or 5V, following the internal

circuit. Thus, circuitry can be damaged, when the sensor input

goes to a Negative level or voltage higher than 5V.

D1

5

V

This manual is related to the following products: