beautypg.com

Securitron PowerJump_ICPT User Manual

Powerjump™ icpt installation instructions, Installation steps, Package contents

background image

Securitron Magnalock Corp.

www.securitron.com

Tel 800.624.5625

ASSA ABLOY, the global leader

in door opening solutions

Securitron Magnalock Corp.

www.securitron.com

Tel 800.624.5625

ASSA ABLOY, the global leader

in door opening solutions

Page 4

© Copyright, 2012, all rights reserved

500-24025

Rev A, 11/12

Page 1

© Copyright, 2012, all rights reserved

500-24025

Rev A, 11/12

Installation Steps

PowerJump™ ICPT

Installation Instructions

Package Contents

Step 1: Survey installation site

Recommended Tools

Screwdriver, drill, center punch

wire nuts (22 gauge), tape

Door Wedge

Rotary tool with cutting wheel

1/4” metal drill bit

82° countersink bit

Wood chisel and hammer

3/32” and 1/16” wood drill bits

1” Auger bit

(4) Metal mounting tabs

(8) Metal mounting spacers

(8) 10/32 flathead machine screws

Unit may be installed on latch side, hinge side, top or bottom of door. Note the ICPT requires a

depth of 1 3/8” in the frame and 1 5/8” in the door.

Input power at frame side:

500mA at 24V DC

Output power (selectable voltage) at door side: 250mA at 24V DC or 500mA at 12V DC

Operating temperature: 32 to 120 F / 0 to 49 C

Maximum gap between faces: 3/16”

Compatibility: PowerJump does not support LBM, REX or other signals from the lock

Step 2: Select the template matching your door and frame material. Apply the

templates as shown at the desired mounting location. Make sure the

center line arrows are aligned when the door is closed.

Questions about Installation?

Contact Securitron at: 1-800-MAGLOCK (800-624-5625)

Wood Mounting Tools:

Metal Mounting Tools:

Specification

Door side unit (red wire)

(4) 8/32 flathead machine screws

(4) Installation templates (not shown)

(4) #8 1” wood screws

(4) #8 2 1/8” wood screws

Frame side unit (purple wire)

Align center line

of templates with

door closed

Scan the QR code

for an online video

How does it work?

Door

Frame

Door

Frame

The PowerJump ICPT transfers power across a door gap through magnetic inductive coupling.

Overview

PowerJump Mounted Dimensions

1 1/4”

1 5/8”

1 3/8”

1 7/8”

2 3/4”

2 1/8”

Wood Mount

Face

Door Unit

1/8” face depth

Hard Wood 3/32” x 3/4” deep

Soft Wood 1/16” x 2” deep

1 1/4”

4”

5”

Metal Mount

Face

1/4” bit (4) places

82° countersink

mounting

tabs (2)

Depth

Frame Unit

Troubleshooting:

Check voltage at frame side unit is within 24V +/- 10%

Check voltage on door side with door closed and unit under load with flying leads

Check air gap between faces is 3/16” or less. Frame side unit can be shimmed outward to improve performance.

Remove unit

Cut shims

Attach

Shims

Replace unit