Installation Steps
PowerJump™ ICPT
Installation Instructions
Package Contents
Step 1: Survey installation site
Recommended Tools
Screwdriver, drill, center punch
wire nuts (22 gauge), tape
Door Wedge
Rotary tool with cutting wheel
1/4” metal drill bit
82° countersink bit
Wood chisel and hammer
3/32” and 1/16” wood drill bits
1” Auger bit
(4) Metal mounting tabs
(8) Metal mounting spacers
(8) 10/32 flathead machine screws
Unit may be installed on latch side, hinge side, top or bottom of door. Note the ICPT requires a
depth of 1 3/8” in the frame and 1 5/8” in the door.
Input power at frame side:
500mA at 24V DC
Output power (selectable voltage) at door side: 250mA at 24V DC or 500mA at 12V DC
Operating temperature: 32 to 120 F / 0 to 49 C
Maximum gap between faces: 3/16”
Compatibility: PowerJump does not support LBM, REX or other signals from the lock
Step 2: Select the template matching your door and frame material. Apply the
templates as shown at the desired mounting location. Make sure the
center line arrows are aligned when the door is closed.
Questions about Installation?
Contact Securitron at: 1-800-MAGLOCK (800-624-5625)
Wood Mounting Tools:
Metal Mounting Tools:
Specification
Door side unit (red wire)
(4) 8/32 flathead machine screws
(4) Installation templates (not shown)
(4) #8 1” wood screws
(4) #8 2 1/8” wood screws
Frame side unit (purple wire)
Align center line
of templates with
door closed
Scan the QR code
for an online video
How does it work?
Door
Frame
Door
Frame
The PowerJump ICPT transfers power across a door gap through magnetic inductive coupling.
Overview
PowerJump Mounted Dimensions
1 1/4”
1 5/8”
1 3/8”
1 7/8”
2 3/4”
2 1/8”
Wood Mount
Face
Door Unit
1/8” face depth
Hard Wood 3/32” x 3/4” deep
Soft Wood 1/16” x 2” deep
1 1/4”
4”
5”
Metal Mount
Face
1/4” bit (4) places
82° countersink
mounting
tabs (2)
Depth
Frame Unit
Troubleshooting:
Check voltage at frame side unit is within 24V +/- 10%
Check voltage on door side with door closed and unit under load with flying leads
Check air gap between faces is 3/16” or less. Frame side unit can be shimmed outward to improve performance.
Remove unit
Cut shims
Attach
Shims