The fourth drawing shows time setting. Note the five position dip switch. Be sure you can
identify the ON/OFF state of each switch. ON is towards the numbers. Switches 1-4 can be set
in 16 different combinations (matrixes) which yield 16 different delay times, in seconds, as are
shown in the chart. The factory set value is 5 seconds which is displayed in the drawing.
Note that actual time can vary by about 10% from the “nominal” time which is
displayed, so test the unit prior to completing the installation. If it is “fast” or “slow”, you can
choose the adjacent Dip Switch Matrix setting to yield the exact time you require.
NOTE: DIP SWITCH #5
SETS VOLTAGE:
ON=12V 0FF=24V
WHITE (REL. COM)
BLUE (REL. N.O.)
MOMENTARY CLOSURE
BETWEEN +V IN
AND TRIGGER
OPERATES RELAY
FOR TIME SET
+
-
YELLOW (TRIGGER)
GREEN (REL. N.C.)
POWER
SUPPLY
TIMEMATE
YELLOW
RED
WHITE
BLACK
POWER
SUPPLY
TIMEMATE
+
-
YELLOW
RED
WHITE
BLACK
SWITCH
D.C. LOCK
FAIL SAFE
GREEN
SPDT
C
NC
NO
BLUE (IF FAIL SECURE)
GREEN (IF FAIL SAFE)
TIMEMATE: GENERAL OPERATION
N.O. SWITCH
12 VDC, 24 VDC OR
24 VAC POWER SUPPLY
RED (+V OR AC IN)
BLACK (NEG OR AC IN)
+ OR
AC
AC
- OR
TIMEMATE: 12 VDC, 24 VDC OR 24 VAC ELECTRIC LOCK CONTROL
LOCK
TIMEMATE: DOUBLE BREAK WIRING FOR FAIL SAFE DC LOCK
TIMEMATE: DIGITAL TIME SETTING
ON
OF
F
12
3
4
5
12 VOLTS
INPUT VOLTAGE SET FOR 24 VOLTS
TIME SETTING MATRIX
TIME SETTING MATRIX
TIME SETTING MATRIX
TIME SETTING MATRIX
SW#1 SW#2 SW#3 SW#4 TIME
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
DIP SWITCH ACCESS
2
4
5
7
12
15
16
18
20
22
24
25
30
32
34
36
NOTE: FACTORY SET 5 SECOND