Securitron DK-XB User Manual
Page 6
![background image](/manuals/349191/6/background.png)
PN# 500-20300
Page 6
Rev. D, 06/11
6. WIRING
The only wiring issues with the expansion board are plugging in the printer DB9 cable, accessing the
contacts
of programmable relay #2 and setting up (if desired) enabling and disabling of the printer from
an external switch. Figure 2 shows these connections. For printer enabling and disabling, the
external switch must connect and disconnect +V (from CPU board terminal “+ IN/OUT”) to
terminal “PT” on the expansion board. Finally, be sure to remove the paper insulator on the
lithium battery which backs up the date and time. This insulator is present so that the battery
will remain fully charged until the product is actually put into use.
FIG. 2: WIRING THE EXPANSION BOARD
PT NC C NO
DB9 CONNECTOR FROM
PRINTER CONNECTS HERE
LITHIUM BATTERY BACKS UP
DATE AND TIME. SHOULD BE
REPLACED EVERY FIVE
YEARS. (TYPE BR 2325)
PROGRAMMABLE
RELAY #2
WHEN CONNECTED TO +V (CPU BOARD
TERMINAL IN/OUT +) BY EXTERNAL SWITCH,
PRINTER IS DISABLED
RIBBON CABLE FROM THIS
SOCKET CONNECTS TO AUX
SOCKET ON DK-26 CPU
BOARD
REMOVE PAPER INSULATOR
TO ACTIVATE LITHIUM
BATTERY
7. MAGNACARE
LIFETIME REPLACEMENT WARRANTY
For warranty information visit: www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/