PN#
500-10650
Page
2
Rev. A, 4/09
Figure 2
Figure 3
(Wood Type Frames)
(Steel Type Frames)
Wood Type Frames – Step-By-Step Installation Procedures:
• Position the bracket in the Magnalock mounting location on the frame.
• Utilizing the bracket as a template, mark the counter-sink holes where the wood screws will
be located.
• Drill the marked locations in the frame using a 7/32” [5.5mm] drill at a minimum depth of
approximately 2-1/2”.
• Mount the bracket onto the frame and securely tighten using the #14 x 4” long wood screws
provided.
• Drill the hole for the cable access into the frame utilizing the slotted area provided in the
center locations of the concrete wood header bracket.
• Position the Magnalock onto the CWB concrete wood header bracket while running the cables
into the cable access area.
• Using the 1/4-20 socket head cap screws provided with the bracket hardware and the flat
washers provided with the Magnalock hardware, securely mount the Magnalock into place.
Steel Hollow and Concrete Filled Type Frames – Step-By-Step Installation Procedures:
• Position the bracket in the Magnalock mounting location on the frame.
• Utilizing the bracket as a template, mark the counter-sink holes where sheet metal screws
will be located.
• Drill the marked locations in the frame using a 3/16” [4.8mm] drill at a minimum depth of
approximately 1-1/2”.
• Mount the bracket onto the frame and securely tighten using the #12 x 1-1/2” sheet metal
screws provided.
• Drill the hole for the cable access into the frame utilizing the slotted area provided in the
center locations of the concrete wood header bracket.
• Position the Magnalock onto the CWB concrete wood header bracket while running the cables
into the cable access area.
• Using the 1/4-20 socket head cap screws provided with the bracket hardware and the flat
washers provided with the Magnalock hardware, securely mount the Magnalock into place.
1/4-20 Socket Cap Screws
(Included)
1/4” Flat Washers
(Included with Magnalock)
#14 x 4” Screw
(Included)
#12 x 1-1/2” Screw
(Included)
CWB - Concrete Wood Header Bracket