36

Robot Waterbase Applicator - Maintenance

Electrical

General Problem

Possible Causes

Corrective Action

1. Cascade not functioning.

1. Exterior of gun contaminated

with conductive material.

1. Cascade failure.

1. Check connection between cascade and

harness (79200-00).

2. Check low voltage cable and harness timing.

Correct as required.

3. Isolation tubes contaminated. Clean and re-

install as required.

4. Fluid hose has pinholled. Replace as required.

5. Cascade bad. Replace as required.

6. Low voltage cable connections wrong at

MicroPak.

7. Low voltage cable bad. Replace as required.

1. Replace gun cover.

2. Clean exterior with a non-polar solvent.

1. Replace as required.

No Electrostics

Low Kv , High µA Output

Low Kv, Low µA Output

AA-03-01.1