29

Robot Waterbase Applicator - Maintenance

Figure 16: Check Valve Removal

1

Valve Manifold

1

2

Check Valve Assembly

1

3

Plug, Check Valve

1

4

Seal

1

5

O-Ring, Solvent Proof

1

6

Valve Removal Tool

1

Item #

Description

Qty.

17. Refer to Figure 16 to remove the air purge check

valve. Remove the check valve plug [3]. Remove the-

seal [4]. Using check valve removal tool (79000-00)

[6], remove the check valve assembly [2]. Remove

the o-ring [5].

5

1

3

2

4

6

AA-03-01.1