24

Robot Waterbase Applicator - Maintenance

Figure 12: Harness Removal

5. Referring to Figure 11, remove the (3) socket

head cap screws [3] and o-rings [4] from the rear of

the gun.

6. Remove the 3/6" OD tubes [11], [12], [13], and [14]

from the barb fittings on the manifold or from the

push-to-lock fittings on the plate assembly [2].

7. Remove the formed tubes [9] and [10] by releas-

ing them from the push-to-lock fittings on the plate

assembly [2]. Disconnect the cascade harness [7]

from the cascade. The plate assembly [2] may now

be removed by pulling the edges away from the

valve manifold.

>

The cascade harness in the RWA-EFM and the

EFM applicators are not interchangeable. Use

only the harness with the tag (79200-00) for the

RWA-EFM applicators. (Reference Figure 12.)

C A U T I O N

!

1

3

5

4

2

HARNESS IDENTIFICATION TAG

USE FOR RWA-EFM ONLY

1

Wiring Harness, Cascade EFM

1

2

Plate, Read RWA-EFM

1

3

O-Ring, Encapsulated

1

4

Set Screw, 3/8" Long X 10-24

1

5

Fitting, Push-To-Lock, 3/16" OD

4

Item #

Description

Qty.

8. Refer to Figure 12 to remove the cascade harness

[1] from the plate. Using a 3/32" wrench, remove the

set screw [4] from the plate assembly [2]. Pull the

harness straight out. Repair/replace as necessary.