24
Robot Waterbase Applicator - Maintenance
Figure 12: Harness Removal
5. Referring to Figure 11, remove the (3) socket
head cap screws [3] and o-rings [4] from the rear of
the gun.
6. Remove the 3/6" OD tubes [11], [12], [13], and [14]
from the barb fittings on the manifold or from the
push-to-lock fittings on the plate assembly [2].
7. Remove the formed tubes [9] and [10] by releas-
ing them from the push-to-lock fittings on the plate
assembly [2]. Disconnect the cascade harness [7]
from the cascade. The plate assembly [2] may now
be removed by pulling the edges away from the
valve manifold.
>
The cascade harness in the RWA-EFM and the
EFM applicators are not interchangeable. Use
only the harness with the tag (79200-00) for the
RWA-EFM applicators. (Reference Figure 12.)
C A U T I O N
!
1
3
5
4
2
HARNESS IDENTIFICATION TAG
USE FOR RWA-EFM ONLY
1
Wiring Harness, Cascade EFM
1
2
Plate, Read RWA-EFM
1
3
O-Ring, Encapsulated
1
4
Set Screw, 3/8" Long X 10-24
1
5
Fitting, Push-To-Lock, 3/16" OD
4
Item #
Description
Qty.
8. Refer to Figure 12 to remove the cascade harness
[1] from the plate. Using a 3/32" wrench, remove the
set screw [4] from the plate assembly [2]. Pull the
harness straight out. Repair/replace as necessary.
AA-03-01.1