28

Robot Waterbase Applicator - Maintenance

12. Refer to Figure 15 to remove the isolation tubes,

fittings, and short tie rod (Steps 12, 13, 14, 15, and

16.) Remove the isolation tube [6] by screwing the

tube counter-clockwise out of the valve maifold by

hand. Remove the (2) o-rings from each end [12]

and [13].

>

This tube should be cleaned with the

appropriate solvent to clean off the mate-

rial being sprayed. Then this tube must be

cleaned with a non-polar solvent.

NOTE

13. Inspect the ID of the tubes for carbon tracking.

If any carbon tracking is seen, the tube must be

replaced. If no tracks are seen, install a generous

amount of LSCH-0009 di-electric grease on the ID

of the tube.

14. Remove the air fittings [5] and barbed fittings

[1], [2], [3], and [4]. When re-installing these fittings,

use a non-conductive pipe thread sealant on the

threads.

15. Remove short tie rod [7] by removing two screws

[8]. Remove tie rod bracket [10] by removing socket

head cap screw [9].

16. Remove shroud o-ring [11] by prying out of

groove.