Your PINKERTON control panel is pre-programmed at the factory and is ready to use
immediately. Before attempting to change any of the factory settings check with your customers
personal needs.
PINKERTON factory default settings:
Entry Delay ......................30 seconds
Exit Delay.........................60 seconds
Master Code .....................1234
Zone 1...............................Entry Delay Zone
Zone 2...............................Handover Zone
Zone 3...............................Handover Zone
Zone 4...............................Instant Zone
Zone 5...............................Instant Zone
Zone 6...............................Instant Zone
Zone 7...............................24hr Zone
Zone 8...............................24hr Zone
Note:
When Armed in Home mode, zones 5 & 6 have been programmed to be isolated.
I
NSTALLER
C
ODE
&
M
ASTER
C
ODE
Factory default I
NSTALLER
code is
The Installer code can:
• Program all addresses except for address 252
• Review the panel memory
Factory default M
ASTER
code is
The Master code can:
• Turn the panel On and Off
• Program User codes
• Program the telephone numbers (Only when Personal dialling format is selected)
• Program address 252 to restrict the installer code
• Review the panel memory
Note: The Master code can completely disable the Installer code.
See notes on address 252 on page 28.