PSA PIN388D/PIN388L Installer Manual User Manual
Page 23

22
PINKERTON Installer Manual
Name of
option
Address
Value allowed
Option Description
Zone Option
Section 2
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
224
226
228
230
232
234
236
238
Select 1 - 8
1 Entry Delay
Setting this option will cause this Zone to be an Entry Delay
Zone. At least one Zone must be made an Entry Delay Zone
for entry delay to operate.
Once the entry timer has started any further inputs triggered
that are programmed as Handover Zones are also regarded
as delayed although the entry timer is not re-started.
2 Home beep
Setting this option will cause this Zone to sound the keypad
beeper in home mode when triggered. If the Home Squawk
option (address 098, option 5) is also on, then the siren will
also squawk momentarily in home mode when this home
Zone is triggered.
3 Siren lockout
Setting this option will cause any Zone to trigger sirens once
only. Note that the dialler may still be re-triggered as long as
the Report Lockout option is off.
4 Report lockout
Setting this option will cause this Zone to report only one
alarm even if triggered more than once. A Zone isolate will
also be sent if programmed by the Send Isolated Zone
Reports option (address 170, option 8). This is independent
of the Siren Lockout option.
5 Home siren
Setting this option will cause this Zone to sound the siren in
home mode when triggered. Note: If disabled then this Zone
will never sound the siren in home mode.
6 Home report
Setting this option will cause this Zone to trigger the dialler in
home mode when alarmed. Note: If disabled then this Zone
will never trigger the dialler in home mode.
7 Home strobe
Setting this option will cause this Zone to turn on the strobe in
home mode when alarmed. Note: If disabled then this Zone
will never turn on the strobe in home mode.
8 Pulse Zone
Pulse count operation applies to Zones 1 to 8. The Zones
may be delayed or instant. Operation is as follows:
When the first Zone with the Pulse Zone option set is
triggered, a pulse timer is started. The pulse timer expires in
the time set at address 244. If the programmed number of
triggers are processed from any pulse count Zone within the
pulse count time, all the triggered pulse count Zones will then
go into alarm. If the pulse timer expires before that required
number of pulse triggers has occurred, then all pulse triggers
to that point are ignored. This feature enables false alarms to
be reduced by specifying at least 2 triggers from a Zone(s)
before considering an alarm condition to exist.