PINKERTON Installer Manual
I
SOLATE
Key
This operation allows Zones 1 - 8 to be manually isolated or re-enabled at any time and is only
available to holders of user codes 0 to 7. The ON-LINE, LOW BATT, AC FAIL and ON lights
will illuminate and the Zone lights will show the current manual isolate status of the Zones.
A Zone light being ON, means that Zone is manually isolated.
As keys
to
are pressed, the relevant Zone light will toggle on or off. When the light is on
the Zone is isolated.
The
key is used to exit out of isolate mode (isolate mode will also end if there are no keys
pressed for 10 seconds).
Note that isolated Zones only remain isolated until the next time the alarm system is turned off,
even if the alarm system is already off. AC fail, Low battery, Panic, Test and Duress inputs
cannot be isolated.
P
ROGRAM
Key
Enter installer or master code followed by
to enter programming mode. Only available to the
master code and the installer code.
O
N
(H
OME
M
ODE
)
Key
Enter any user code followed by
or enter
to turn the system on in Home Mode. ON
light will flash to indicate system is armed in home mode. Only Zones which are programmed as
Home Zones will be active.
O
N
(A
WAY
M
ODE
)
Key
Enter
followed by any user code followed by
or enter
to turn the system on in Away
Mode. ON light will turn on to indicate alarm system is armed in Away Mode. Only Zones which
are programmed as Away Zones will be active. All user codes are allowed to arm the alarm
system.
If Power Codes are enabled, (address 096, option 7), then codes 8 - 15 do not need to use
to
turn ON).