PSA PIN388D/PIN388L Installer Manual User Manual
Page 19

18
PINKERTON Installer Manual
A
DDRESS
D
ESCRIPTIONS
–
U
SER
C
ODES
Name of
option
Address
Value allowed
Option Description
User 0
Master Code
000
4 digits
The Master code can turn the alarm ON and OFF and change
user codes and the temporary telephone number as well as
functions at address 252.
User 1
Installer Code
004
4 digits
The Installer code has access to all functions(except arming
and disarming) and addresses except address 252. The
Installer code can be disabled by the Master code at address
252.
User 2
008
4 digits
Has access to all functions except programming
User 3
012
4 digits
Has access to all functions except programming
User 4
016
4 digits
Has access to all functions except programming
User 5
020
4 digits
Has access to all functions except programming
User 6
024
4 digits
Has access to all functions except programming
User 7
028
4 digits
Has access to all functions except programming
User 8
032
4 digits
Can only turn the system ON and OFF
User 9
036
4 digits
Can only turn the system ON and OFF
User 10
040
4 digits
Can only turn the system ON and OFF
User 11
044
4 digits
Can only turn the system ON and OFF
User 12
048
4 digits
Can only turn the system ON and OFF
User 13
052
4 digits
Can only turn the system ON and OFF
User 14
056
4 digits
Can only turn the system ON and OFF
Usr 15
060
4 digits
Can only turn the system ON and OFF
- To erase a code, enter
in place of the first digit.
- See address 096, option 7 for information on the use of user codes 2 - 15 as Power Codes.
Master
Installer
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Turn ON/OFF Home mode and Away mode Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Keypad Panic Y
Y
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Keypad Duress Y
Y
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Keypad Test Y
Y
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Y¹
Isolate zones Y
Y
Y
Y
Y
Y
Y
Y
Review memory Y
Y
Y
Y
Y
Y
Y
Y
Program User codes Y
Y
Program Temporary telephone number Y
Y
Program system addresses
Y
Program address 252 Y
Program address 255
Y
Panel reset Y
Y
Remote access by telephone Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Remote access by PSA-Connect
Y
¹ If Powercodes are enabled, Codes 2-15 do not have access
to Panic, Duress, Test functions at the keypad.