PSA PIN388D/PIN388L Installer Manual User Manual
Page 13

12
PINKERTON Installer Manual
REVIEW
Key
Enter a user code followed by
or simply enter
to enter review mode. The ON-LINE,
LOW BATT, AC FAIL & ON lights will all be on to indicate you are in review mode. Review
mode displays a history of past alarms and events stored in the alarm’s memory.
This alarm memory is permanently stored and can be cleared by your installer or by pressing the
key while in review mode.
(Please note that your entry delay Zone/s will always be stored in memory, even if they have not
alarmed.)
While in review mode, various events will be displayed by pressing the following keys:
Key
Displays past Zone alarms since alarm memory last cleared.
Key
Displays past alarms other than Zones.
Key
Display previous events (miscellaneous).
Key
Clear review memories.
Key
Displays the PINKERTON’s software version. (in binary).
Key
Exit review mode.
When first entered, review shows past Zone alarms. The following tables show how to interpret
the various displays:
REVIEW
Previous Zone Alarms
While in REVIEW mode, pressing Key
displays:
Zone
Light Meaning
1 - 8
Previous alarm on Zones 1 - 8 since system last armed.
Note: The first Zone that was triggered will be flashing.
REVIEW
Previous Non-Zone Alarms
While in REVIEW mode, pressing Key
displays:
Zone
Light Meaning
1 Duress
input
triggered.
2 Panic
input
triggered.
3
Test input triggered.
4
Low Battery input triggered.
5
AC Fail input triggered.
6
On input triggered.
7 Fail-to-communicate
input
triggered.
8 Spare
input
triggered.