PSA PIN388D/PIN388L Installer Manual User Manual
Page 35

34
PINKERTON Installer Manual
Name of
option
Address
Value allowed
Option Description
Dialler options
170
Select
1, 2, 6, 7, 8
1 Rotary
Dial.
The system is factory programmed for tone dialling. Select
this option to enable rotary (decadic) dialling.
2 Open
after
alarm.
When this option is selected, the system will send an
opening report only if Zone alarms have occurred during
the last armed period. This reduces the number of
telephone calls made but allows the central station to be
informed when an authorised access is taking place after
an alarm has occurred.
To use the open after Zone alarm facility:
Enable Open After Alarm at address 170, option 2.
Disable all options at address 064 except for option 8.
Note that when the Open After Alarm option is set, the
central station will never receive a closing report.
3 not
used
4 not
used
5 not
used
6 Send Zone ID (Personal dialling)
Option ON: The called phone hears a number of beeps
equal to the Zone number which triggered the alarm.
Option OFF: The called phone hears a high/low siren
tone.
7 Send
restoral
reports
When selected, the system will send a restoral report to
the monitoring station when the alarmed input has
resealed.
8 Send isolated Zone reports
When selected, the system will send isolated Zone reports
to the monitoring station along with the closing report
when the system is turned on.
Dialler format
174
Select 0, 1, 3, 4
0 Disables dialler (handy installer option for temporary or
permanent disabling of dialler)
1 Ademco high speed with checksum
2 not
used
3 Contact
ID
4 Personal
dialling
Maximum
dialling
attempts
175
00 - 10
attempts
Sets the maximum number of attempts the dialler will make
when triggered. Factory default is 6 attempts. Do not set to
over 10 attempts.