PINKERTON Installer Manual
21
A
DDRESS
D
ESCRIPTIONS
–
L
OCAL
&
D
IALLER
V
ERSIONS
Name of
option
Address
Value allowed
Option Description
Zone Option
Section 1
&
System
Inputs
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Open/Close
Fail to Comm
Duress Input
Panic Input
Test Input
Low Battery
AC Fail
070
072
074
076
078
080
082
084
064
066
086
088
090
092
094
Select 1 - 8
1 Handover
Zones selected for handover have entry delay as long as a
delayed Entry Delay Zone has been triggered first (see
next page). If a Handover Zone is triggered before an Entry
Delay Zone, the alarm will be instant. Note that delay will
be ignored if selected for 24 hour inputs. In home mode,
there will be no delay if the Home Instant option is set
(address 098, option 7).
If during entry delay an instant alarm occurs, this will be
actioned immediately without affecting the delayed inputs
operation.
If the system is turned ON in Home Mode and Home
Instant (address 098, option 7) has been enabled, then all
delayed inputs will be instant while the panel is in Home
Mode. All 24 hour inputs are treated as instant even if they
have been programmed for Handover or Entry Delay.
At the end of the entry delay, all delayed inputs that were
triggered will go into alarm unless the panel has been
turned OFF before the end of the entry delay.
2 Siren
Any active input can be programmed to trigger the siren.
When in Home Mode, there is a separate option for
enabling sirens for any Zone, see: Zone Options Section 2.
3 Dialler
Zones selected for dialler will trigger the dialler when
alarmed. If a Zone is triggered in Home Mode, it will only
trigger the dialler if the Home Report option is on. Selecting
Dialler for the Fail to Communicate input will be ignored.
4 Autoisolate
Zones selected for auto-Isolate will be isolated if still un-
sealed at the end of exit delay. Generally speaking the
Auto Isolate option is not programmed for 24 hour inputs
5 Strobe
Any active input can been programmed to trigger the
strobe. When in Home Mode, there is a separate option for
enabling strobe for any Zone, see: Zone Options Section 2.
6 Away
Zones selected for Away will be armed at the end of exit
delay when panel is turned on in Away mode.
7 Home
Zones selected for Home will be armed at the end of exit
delay when panel is turned on in Home mode.
8 24hr
Zones selected as 24hr will be permanently armed.
Note:
The system must be reset for this change to take
effect.