PSA PIN388D/PIN388L Installer Manual User Manual
Page 33

32
PINKERTON Installer Manual
D
IALLER FUNCTIONS
P
ERSONAL
R
EPORTING
Personal reporting allows dialler reports to be sent to a person rather than a central station if an
alarm occurs. When an alarm occurs, the
system
will immediately seize the line and dial a pre-
programmed number. The
system
will then output an alternating high/low siren type sound to
indicate that an alarm has occurred.
If Send Zone ID (address 170, option 6) is set then the
system
will output a series of beeps, the
number of beeps equal to the Zone number that was triggered.
Every 10 seconds the tones will pause, allowing any key to be pushed to acknowledge the call and
cause the
system
to announce the current state of the panel, 1 beep for off, 2 beeps for on. Pressing
may now be used to hang-up the
system
immediately or it will hang-up anyway after 15
seconds. During this time the
system
can be turned on or off.
If after one minute no key has been pressed, the
system
will hang up and try again. See page 35,
section on Operation of Telephone Numbers for retry logic.
During reporting in personal format mode, prior to a key being pushed by the answering party, the
report may be aborted by entering any valid code on the PINKERTON keypad. Note that once the
called party has pushed a key, the PINKERTON keypad lights will flash indicating that the called
party is in control.
A special temporary telephone number can be programmed by the master code to replace the
primary telephone number. When programmed, this number will replace the primary telephone
number until the panel is next turned off from away mode, at which time the first digit of the
temporary number is erased (disabling the temporary number) and operation will revert to the
primary telephone number.