PERKO 1150 User Manual
PERKO Lighting

16490 N.W. 13th Avenue
Miami, FL 33169-5707
Scale: None
Date: 8/24/82
Revised: 12/2/08
Drawn By: D. Beutler
FIG. 1150RE1 AND 1150GE1
PORT AND STARBOARD SIDE NAVIGATION LIGHTS
No.
Name of Piece
No. Req.
Material
Size & Spec.
1
Cap & Cable
1
Polycarb.
Fig. No. 1105
2
O-Ring Fig. No. 1119
1
Neoprene
4-5/8x4-1/4x1/8
3
Body
1
Brass or
20 GA-.032
Galv. Steel
4
Lens
1
Polycarb.
See Note #1
5
Socket Support Stand
1
Brass
Fig.No. 034-001PLB
6
Socket
1
See Note #2
7
Socket, Mounting Screws
2
S/S
8-32 x 3/4” R.H.
8
Ground Screw & Nut
1
S/S
8-32 x 3/4” R.H.
9
Packing Nut & Gland Ring
1
Polycarb.
for 7/16” Cable
10
Certification Plate
1
Brass
Not Available As Repl Pt.
11
Mounting Bracket
1
Aluminum
Fig. No.0143000ALU
Bill of Material
NOTES:
1. Lens
- Red - Port Side: Cat. No. 0259001RED
Green - Starboard Side: Cat. No. 0259001GRN
2. Socket - Medium Prefocus: Cat. No. 0347A
3. Weight - 4Lbs. - 9 ozs
For Vessels
20 Meters (65.6 Ft.) to 50 Meters (164.0 Ft.) in Length
Cat. No.
Finish
Description
Visible
Visible
Reg.
Lamp
Arc
Miles
Watts
Cat. No.
1150RE1GAL
Galv Steel
Red Sidelight
112-1/2°
2
25
0342000CLR
1150RE1PLB
Pln Brass
Red Sidelight
112-1/2°
2
25
0342000CLR
1150RE1POL
Pol Brass
Red Sidelight
112-1/2°
2
25
0342000CLR
1150GE1GAL
Galv Steel Green Sidelight 112-1/2°
2
25
0342000CLR
1150GE1PLB
Pln Brass
Green Sidelight 112-1/2°
2
25
0342000CLR
1150GE1POL
Pol Brass
Green Sidelight 112-1/2°
2
25
0342000CLR
VISIBILITY AND WATTAGE SPECIFICATIONS*
*Bulb Data - These are special PERKO Navigation Lamps, 120 Volts,
T-10, Prefocus Base, C-8 Filament, Clear 2-3/8 Inch
L.C.L., and must be used to meet the ‘72 COLREGS.
These navigation lights meet the U.S. Coast Guard Requirements
under the ‘72 COLREGS and are classified by Underwriters’
Laboratories Standard U.L. 1104 to meet the ‘72 COLREGS.
NOTE:
WIRE ONLY THROUGH TERMINAL TUBE USING 16/3
SO CABLE WITH 7/16 INCH NOMINAL O.D. TO
RETAIN WATERTIGHT INTEGRITY AND COMPLY
WITH U.L. 1104.