2.4.3 Number of Rings to Ring Residence
Default setting is 05 (5 Rings).
This programming step is only used if the Access Plus unit is connected with the 1816 Access
Plus interface. This programming step is not applicable when the Access Plus unit is used as
an auto-dialer. This programming sequence sets the number of unanswered rings to the apartment
before the Access Plus unit hangs up.
1. Press * 6 4 and then enter the MASTER CODE. [ * 6 4 _ _ _ _ (beep)]
2. Enter the number of rings before unit hangs up (01-99) then press *. [ _ _ * (beep)]
3. Press 0# TOGETHER to end. [0# (beeeeeep)]
2.4.4 Talk
Time
Default setting is 060 (60 Seconds).
This programming sequence sets the maximum time allowed for conversation when the Access Plus
unit places a call either through the 1816 telephone intercom interface (directory codes 01-23) or
through the auto-dialer (directory codes 24-50). Talk time can be set from 10 seconds up to 255
seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk
time of 30 seconds, enter 030 in step 2.
1. Press * 0 8 and enter the MASTER CODE. [ * 0 8 _ _ _ _ (beep)]
2. Enter the talk time code (010-255) then press *. [ _ _ _ * (beep)]
3. Press 0# TOGETHER to end. [0# (beeeeeep)]
2.4.5 Relay Strike Time
Default setting for Relays 1 and 2 is 01 (1 Second). Relays 3 through 8 are not set.
These steps will program the system relay strike times. Strike times can be programmed from 1/4
second (enter 00 in step 3) up to 99 seconds.
System relays 1 and 2 are the two relays on the Access Plus unit main circuit board. System relays 3
through 8 are the relays associated with additional RS-485 devices (card readers, keypads, RF
receivers, etc.) connected to the system.
1. Press * 0 3 and enter the MASTER CODE. [ * 0 3 _ _ _ _ (beep)]
2. Enter a relay number (1 – 8), then press *. [ _ * (beep)]
3. Enter the two-digit strike time (00-99) then press *. [ _ _ * (beep)]
4. Repeat steps 2 and 3 to set other relay strike times.