Optional flush valve configurations, Assemble mix housing – Magnum Venus Plastech Classic Pro Gun CPC_CPG_CPW_CPP User Manual
Page 29

Classic Pro Gun Manual
Rev. 08/2012
Page | 29
Optional Flush Valve Configurations:
There are several variations on the flush valve assembly to include air / solvent purge
and high pressure flush. Check the parts drawing for the valve assembly installed on
your gun assembly.
5104-01-01
Standard Flush Valve Assembly
SAPV-1000-INT Solvent / Air Purge Assembly
– international
SAPV-1000
Solvent / Air Purge Assembly
BVF-1000
Ball Valve Flush Assembly
– for high pressure flush
Assemble Mix Housing
1.
Install the distribution ring (5104-17-1 Standard) into the mix housing
Note: Be sure the distribution ring is positioned correctly. The chamfered or
beveled edge of the hole should face away from the turbulent mixer and toward
the gun block.
Note: Be sure the holes in the distribution ring are clean and free of debris or
hardened material.
2.
Position the mix housing seal into the mix housing, against the distribution ring.
3.
Insert the catalyst injector assembly (5104-03-01) and injector seal into the
center hole of the distribution ring. The spring should be facing up, as it will go
into the gun block and the injector seal will be against the gun block.
4.
Use the socket cap screws (7102-1-6) to attach the mix housing to the gun block
WARNING: Screws and fasteners provided with this Pro Gun ™ are specially
designed for this equipment. Use only Magnum Venus Product replacement
parts, or warranty may be voided.
5.
Insert the turbulent mixer into the mix housing.
6.
Apply some red grease to the threads of the mix housing and nozzle cap. This
will make them easier to remove later.
7.
Install the nozzle into the nozzle cap (8704-4-1). See above for nozzle selection.
8.
Screw the nozzle and nozzle cap onto the mix housing.