beautypg.com

Reinstall check valve on international pro guns, Reinstall catalyst plug on domestic pro guns, Reassemble flush valve – Magnum Venus Plastech Classic Pro Gun CPC_CPG_CPW_CPP User Manual

Page 28

background image

Classic Pro Gun Manual

Rev. 08/2012

Page | 28

Reinstall Check Valve on International Pro Guns

DANGER: To replace this valve, contact Magnum Venus Plastech. These valves
have undergone specific remanufacture at Magnum Venus Plastech for the Pro
Gun ™. Using a check valve not obtained directly from Magnum Venus Plastech
may result in contamination and /or dangerous ignition of the catalyst.

1.

Reinstall the check valve (5104-04-01) and o-ring (O-S-5-125) into the side port
on the catalyst side of the gun block.

Or

Reinstall Catalyst Plug on Domestic Pro Guns

2.

Thread the catalyst plug (5104-32-1) and o-ring (O-S-5-125) into the side port on
the catalyst side of the gun block

Reassemble Flush Valve

1.

Place the o-ring (O-K-008) on the flush valve button (5104-25-1).

2.

Insert the spring (9203-2-3) onto the flush valve button.

3.

Push the button and spring into the flush valve body (5104-24-1).

4.

Place the o-ring (O-A-007) on the flush seal body (5104-23-1).

5.

Insert a flush seal body (5104-23-1) into the end of the flush valve body and
screw it onto the button.

6.

Place a flush valve seal (5104-26-1) on the flush valve body.

7.

Install the flush valve body (5104-24-1) into the flush valve neck (5104-22-1).

8.

Install the split seal (5104-21-1) onto the flush valve body (5104-24-1).

9.

Screw the flush valve assembly (5104-01-01) into the front side port on the resin
side of the gun block

Note: If using o-ring part number O-K-008 (o-ring is used on the flush button),
you do not need to replace the o-ring unless it is showing obvious signs of wear
or damage. This o-ring is specially designed for use with all solvents.

Note: In some cases O-K-008 o-ring can be replaced with the more economical o-
ring (O-E-008)