Safety precautions, Warning warning warning warning warning – Liquid Controls MS Meters User Manual
Page 3

3
Safety Precautions
NOTICE:
This manual provides warnings and procedures that are
intended to inform the owner/operator of the hazards
present when using the Liquid Controls Meter on LPG
and other products. The reading of these warnings and
the avoidance of such hazards is strictly in the hands of
the owner/operator of the equipment. Neglect of that
responsibility is not within the control of the manufacturer
of the meter.
SAFETY PROCEDURES:
Remember to relieve internal pressure before
disassembly or inspection of the strainer, vapor eliminator,
valves, POD pulser, and the front or rear covers. See
“Meter Maintenance” on Page 15 for the steps to relieve
internal pressure in your system.
BE PREPARED:
•
Make sure that all necessary safety precautions have
been taken. Provide for proper ventilation,
temperature control, fire prevention, evacuation, and
fire management.
•
Provide easy access to the appropriate fire
extinguishers for your product. Consult with your local
fire department, state, and local codes to make sure
that you are adequately prepared.
•
Read this manual as well as all the literature provided
in your “Owner’s Information Packet”. If you have
any questions, consult your full-service distributor or
call the Service Department at Liquid Controls.
IN THE EVENT OF A GAS LEAK:
In the event of a large gas leak:
Evacuate the area and notify the fire department.
In the event of a small, contained gas leak:
1.
Stop the leak.
2.
Prevent accidental ignition.
3.
Prevent entrance of gas into other portions of the
building. Some gases, such as LPG, seek lower
levels, while other gases seek higher levels.
4.
Evacuate all people from the danger zone.
5.
See that the gas is dispersed before resuming
business and operating motors. If in doubt, notify your
local fire department.
IN THE EVENT OF A GAS FIRE:
In the event of large fires or fires that are spreading:
1.
Evacuate the building and notify your local fire
department.
2.
Stop the leakage only if the equipment can safely be
reached.
In the event of small, contained fires that you can safely
control:
1.
Stop the leakage only if the equipment can safely be
reached.
2.
Use the appropriate extinguisher: Class B fire
extinguisher, water, fog, etc., depending on the
materials. If in doubt, call your local fire department.
All internal pressures must be relieved before disassembly of the meter, strainer, vapor eliminator,
any valves in the system, the pulse output device, or the front and rear covers. LINE PRESSURE
MUST BE 0.0 PSI. See “Meter Maintenance” on Page 15 for the procedures to relieve internal
!
!
!
!
!