beautypg.com

Laurel Electronics LAUREATE SERIES COUNTER_TIMER User Manual

Page 7

background image

-5-

RS - 485 INTERFACE - J3A & J3B

ISO GROUND

B R X
A R X

ATX

B T X

ISO GROUND

BCD OUTPUT

2
8
20
80
200
800
2K
8K
20K
80K
200K
800K
DATA READY
BCD ENABLE
ISO 5 / 15VDC

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29

2
4
6
8

10
12
14
16
18
20
22
24
26
28
30

1
4

10
40

100
400

1K
4K

10K
40K

100K
400K

+ POL

BCD HOLD

ISOLATED GND

4.5

J3 DIGITAL INTERFACE

*

This configuration is directly compatible with the optotransistor output board.

RELAY OUTPUTS

4.4

J 2 - DUAL SETPOINT CONTROLLER

COMPUTER

GROUND
TRANSMIT +
TRANSMIT -
RECEIVE -
RECEIVE +
GROUND

1
2
3

4
5
6

ALARM 1 - N/O CONTACT

ALARM 1 - N/C CONTACT
ALARM 1 - COMMON

ALARM 2 - N/O CONTACT

ALARM 2 - N/C CONTACT
ALARM 2 - COMMON

1
2
3
4
5
6

ALARM 1 - SOURCE 1
ALARM 1 - SOURCE 2

ALARM 1 - DRAIN

ALARM 2 - SOURCE 1
ALARM 2 - SOURCE 2

ALARM 2 - DRAIN

AC
AC

AC
AC

SOLID STATE RELAY OUTPUTS

Switching AC 125Vac @120 ma max.

1
2
3

4
5
6

ALARM 1 - SOURCE 1
ALARM 1 - SOURCE 2

ALARM 1 - DRAIN

ALARM 2 - SOURCE 1
ALARM 2 - SOURCE 2

ALARM 2 - DRAIN

SOLID STATE RELAY OUTPUTS

Switching DC 125Vdc @240 ma max.

+ DC
+ DC

- DC

+ DC
+ DC

- DC

6
5
4
3
2
1

RS - 232 INTERFACE - J3A

N/C

ISO GROUND

R X

T X

RTS

N/C

6
5
4
3
2
1

COMPUTER

GROUND
TRANSMIT
RECEIVE
RTS

1
2
3

4
5
6

ALARM 1 - SOURCE 1
ALARM 1 - SOURCE 2

ALARM 1 - DRAIN

ALARM 2 - SOURCE 1
ALARM 2 - SOURCE 2

ALARM 2 - DRAIN

SOLID STATE RELAY OUTPUTS

Switching DC 125Vdc @120 ma max.

+ DC

- DC

+ DC

- DC

*

4.6

J4 - ANALOG OUTPUT

1
2
3

0 TO 20 MA OUTPUT

0 TO 10 VDC OUTPUT

ISOLATED GROUND

FULL DUPLEX

COMPUTER

GROUND

TX/RX -
TX/RX +
GROUND

6
5
4
3
2
1

HALF DUPLEX

ISO GROUND

ATX/ARX

BTX/BRX

ISO GROUND