Ordering guide – Laurel Electronics LAUREATE SERIES COUNTER_TIMER User Manual
Page 2
![background image](/manuals/336108/2/background.png)
L ........... Laureate series counter/timer with
screw terminal connectors.
Display Color
5 ................................................ Green LED
6 ....................................................Red LED
7 ............................... Extended capabilities,
custom curves, Green LED
8 ............................... Extended capabilities,
custom curves, Red LED
Power
0 ..................... 85 to 264Vac, 90 to 370Vdc
1 ........................... 9 to 32 Vdc, 8 to 28 Vac
Setpoint Output
0 .......................................................... None
1 ........................................Dual 10 A relays
2 .................Opto isolated solid state relays
Analog Output
0 .......................................................... None
1 ............................ 0 to 20 mA, 0 to 10 Vdc
2 .......Batch relay(for FR batch mode only)
Digital Interface
0 .......................................................... None
1 ...................................................... RS-232
2 ...................................................... RS-485
3 ........................................................... BCD
Input Type
Select one of the following input option boards:
Dual Channel Pulse or AC
Basic: Frequency, rate, period, total, time
interval
Extended: Basic plus rate and total, ratio,
phase angle. stopwatch, arithmetic func-
tions, batching, linearize curves
Channel A: Dc to 1MHz, Channel B: Dc to
250kHz, 20mV to 250V, NPN, PNP, contact
closure, logic level inputs, selectable debounce
and frequency response
FR ................................. Scalable to 999,999
Analog Input
Basic: rate, square root, flow
Extended: basic plus rate and total, square
root, batching, linearize curves
Voltage to Frequency converter, single chan-
nel, displays to +/-999,999
VF1 ............................................... 4 to 20mA
VF2 ................................................ 0 to 1 mA
VF3 .................................................. 0 to 10V
Quadrature
Basic: position,length, angle
Extended: basic function or rate
Count input x1, 2, or 4, anti-jitter circuitry, z
channel zeroing, inputs are differential line
receivers or logic levels.
QD ........................................ Position,length
Remote Display
6-digit display plus minus sign. Accepts RS-
232 or RS-485 from computer, PLC, or other
Laurel meters and displays transmitted value.
Displayed value may be retransmitted as 0 to
10V or 4 to 20mA via the analog output and
setpoints may be added to provide alarms
from displayed value or alarm data via the
serial interface. Requires RS485 or rs232
interface.
No letters after model # ............ +/-99999
ORDERING GUIDE