beautypg.com

Laurel Electronics LAUREATE SERIES COUNTER_TIMER User Manual

Page 13

background image

VALUE SELECT KEY

MENU KEY

DIGIT SELECT KEY

DUAL CHANNEL SIGNAL CONDITIONER (CONT'D)

InPut

Input signal type (cont"d)

A + b

calculates period

for input A (I2), period for
input B (I3), and sum of both
inputs (I1)

A - b

calculates period

for input A (I2), period for
input B (I3), and difference of
both inputs (I1)

A . b

calculates period

for input A (I2), period for
input B (I3), and product of
both inputs (I1)

A / b

calculates period

for input A (I2), period for
input B (I3), and ratio of both
inputs (I1)

A b

calculates totals

for inputs A (I1) & B (I2)

A OnLy

calculates totals

for input A (I1)

A-BUpDn

calculates dif-

ference (I1) between A total
and B total

bursT

calculates total #

of bursts (I1) and burst fre-
quency (I2), input A

b Arat

calculates total for

input b (I1) and rate for input
A(I2)

A bUPd

calculates total

for input A (I1) with input B
up/down control

A binH

calculates total for

input A (I1) with input B as
count inhibit control

A + b

calculates total for

input A (I2), total for input B
(I3), and sum of both inputs
(I1)

PEriod

Period (cont'd)

Note:
(I1), (I2), and (I3) are display
items 1, 2, and 3. The value
that is displayed may be se-
lected via front panel
pushbutton.

Basic counter:
A b, A Only
Extended counter:
All items shown

totAL

Total
Note:
To count down, use negative
scale factor.

Basic counter:
A b, A Only
Extended counter:
All items shown

-11-