beautypg.com

Laurel Electronics LAUREATE SERIES COUNTER_TIMER User Manual

Page 18

background image

-16-

DIGIT SELECT KEY

VALUE SELECT KEY

MENU KEY

0

Unfiltered peak value

1

Filtered peak value

0

Low adaptive threshold

1

High adaptive threshold

0

No filter

1

0.1 sec

2

0.2 sec

3

0.4 sec

4

0.8 sec

5

1.6 sec

6

3.2 sec

7

6.4 sec

0

Positive slope

1

Negative slope

0

Positive slope

1

Negative slope

Use value select key to se-
lect decimal point

Use value select key to se-
lect decimal point

Select 0 through 9 for
flashing digit. Decimal point
fixed. Select scale factor
multiplier

Select 0 through 9 for
flashing digit. Decimal point
fixed by DecPt1.

Select 0 through 9 for
flashing digit. Decimal point
fixed by input range on V-F

Select 0 through 9 for
flashing digit. Decimal point
fixed by DecPt1.

Select 0 through 9 for
flashing digit. Decimal point
fixed by input range on V-F

00000

Peak value

00000

Adaptive filter threshold

00000

Filter time constant

00

Channel A input

00

Channel B input

1.11111 11.1111 111.111
1111.11 11111.1 111111.

2.22222 22.2222 222.222
2222.22 22222.2 222222.

0.00000 0.00000 0.00000
0.00000 0.00000 0.00000

Scale factor

0.00001

to

100000

Multiplier

0000.00 0000.00 0000.00

0000.00 0000.00 0000.00

0.00000 0.00000 0.00000

0.00000 0.00000 0.00000

0000.00 0000.00 0000.00

0000.00 0000.00 0000.00

0.00000 0.00000 0.00000

0.00000 0.00000 0.00000

FiLtEr

Filtering (continued)

SLOPE

Trigger slope of input signal
(if not V-to-F)

dEc.Pt1

Decimal point selection

dEc.Pt2

Decimal point selection

SCALE1

Scale factor and multiplier
(Scale and Offset selected)

OFFSt1

Offset or Zero Value

Lo in1

Low signal input value

(Coor-

dinates of 2 points selected)

Lo rd1

Low Displayed Reading at
Low Signal Input

Hi in1

High signal input value