Control connection diagrams, Gl board j1 terminal block – Controlled Products Systems Group SW4705011G3 User Manual
Page 36

c 2002, The Chamberlain Group, Inc.
All rights Reserved
01-18452D
STOP/RESET
CONTROL INPUT (N.C.)
RESIDENTIAL RADIO
(SINGLE BUTTON) INPUT (N.O.)
HARD CLOSE
CONTROL INPUT (N.O.)
SHADOW LOOP
INPUT (N.O.)
SOFT OPEN
INPUT (N.O.)
HARD OPEN
CONTROL INPUT (N.O.)
INTERRUPT (SAFETY)
LOOP INPUT (N.O.)
OBSTRUCTION CLOSE
EDGE/PHOTO EYE INPUT (N.O.)
GL BOARD
J1 TERMINAL BLOCK
NOTE: SEE WIRING DIAGRAMS SHIPPED
WITH KIT FOR ADDITIONAL INFORMATION.
SEE OWNERS MANUAL FOR WIRING
DISTANCES AND WIRE GAUGE
INFORMATION.
WARNING: All controls that are to be used to
operate the gate system, MUST be installed
where the user cannot come into contact with the
gate while operating the controls. Also, always
install the controls where the user has full view of
gate operation.
* All inputs are normally open and momentary,
except the stop (N.C.). The following instructions
are based upon UL 325, and include
recommendations for significant increase in
safety.
* We strongly recommend that you follow the UL
guidelines presented throughout the manual.
Installation device instructions - always follow the
instructions provided by the manufacturer when
installing and adjusting any control device. If
these instructions are contrary to the advice given
here, call for assistance.
OBSTRUCTION OPEN
EDGE/PHOTO EYE INPUT (N.O.)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
R2
R1
24 VAC
R4
R3
24VAC ACCESSORY POWER MAY BE
FOUND ON THESE TERMINALS
CONTROL CONNECTION DIAGRAMS
VISIT US AT WWW.LIFTMASTER.COM