Program settings (dip switch #4), Figure 1, Street – Controlled Products Systems Group SW4705011G3 User Manual
Page 23: Complex or parking lot

23
STREET
INTERRUPT
LOOP
COMPLEX
OR
PARKING LOT
INTERRUPT
LOOP
(GATE CONDUIT)
SEE FIGURE 1
MASTER
SECOND
SHADOW
LOOP
EDGE/PHOTO OPEN
This switch (S2-3) selects edge or photo sensor for the
gate opening protection input.
Open Photo Eye (Pause): When the controller is config-
ured for photo eyes, the input functions to pause the gate
during the opening cycle. Once the input is cleared the
gate continues to open.
Open Edge: When the controller is configured for safety
edges, the input functions to reverse the gate to the close
limit when the edge is activated during the opening cycle.
CLED PH
OPED PH
CLED PH
OPED PH
1 2 3 4
ON
W
ARN
MA
G
ON
S2
1 2 3 4
ON
W
ARN
MA
G
ON
S2
EDGE OPEN
PHOTO OPEN
CLED PH
OPED PH
CLED PH
OPED PH
1 2 3 4
ON
W
ARN
MA
G
ON
S2
1 2 3 4
ON
W
ARN
MA
G
ON
S2
EDGE CLOSE
PHOTO CLOSE
DUAL GATE COMMUNICATIONS
The controller is capable of running the operator in a master or sec-
ond mode depending on (S4) switch setting.
Before initiating any command the master unit queries for the pres-
ence of a “second unit” for a time period of one second. If the master
gets no response the operator will operate in a stand alone mode.
NOTE: For single unit applications, a jumper must be placed
between J4-1 and J4-2. In this mode no further communications will
take place during travel. If the master detects the presence of a sec-
ond unit the master will continue to query the second unit during trav-
el. The second unit will send a response to the master for every
query. The second operator will stop if there is a period of one sec-
ond or more of no communications.
When two operators are connected in dual gate configuration acces-
sories may be connected to either the master or second.
PROGRAM SETTINGS (DIP SWITCH #2) CONT’D
PROGRAM SETTINGS (DIP SWITCH #4)
ON
MASTER
UNIT
S4
SECOND
UNIT
MASTER
UNIT
SECOND
UNIT
MASTER OR STANDALONE
GATE SETTING
SECOND GATE
SETTING
ON
S4
EDGE/PHOTO CLOSE
This switch (S2-4) selects edge or photo sensor for the gate
closing protection input.
Close Photo Eye (Reverse): When the controller is config-
ured for photo eyes, the input functions to reverse the gate to
the open limit when activated during the close cycle.
Note: Timer to close will reset if enabled.
Close Edge: When the controller is configured for safety
edges, the input functions to reverse the gate to the open limit
when activated during the close cycle. The entrapment is not
cleared at the limit and the timer to close will be disabled. The
timer to close may be enabled by activating the interrupt loop,
soft open or hard open input.
CONNECTOR J4
2
1
CONNECTOR J4
1
2
CONDUIT
SHIELDED CABLE
(TWISTED PAIR)
MINIMUM 18 GAUGE
FIGURE 1
NOTE: Do not run Master/Second communication wiring in
the same conduit as the power and control wiring.
NOTE: The Second unit will require a normally close stop
circuit for proper system operation.
NOTE: After Master/Second wiring has been completed
and the S4 switch programmed, both units must have their
power cycled to initiate proper Master/Second communica-
tion.
NOTE: The motor learn function must be completed in