OPTIONAL CONTROL DEVICES
All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon
UL 325, and include recommendations for significant increase in safety.
We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions
shipped with optional control devices for mounting, wiring, programming and adjustment.
Terminals 1 & 5 - Residential Radio (single button) Input
These terminals are intended for use with a radio receiver
in a residential application or as a single button control.
This allows the user to open the gate by activating the
transmitter when the gate is closed or between limits. This
input also gives the user the ability to close the gate by
activating the transmitter when the gate is on the open
limit.
Terminals 2 & 5 - Shadow Loop Input
These terminals are intended for use with a loop detector
and is primarily used on swing gate operators. This input
protects cars by preventing the gate from moving off of the
open or close limit when the shadow loop input is active.
Terminals 6 & 5 - Soft Open
These terminals are intended for use as a general open
control. Accessories that may be wired to this input
include: Telephone Entry Systems, Radio Receiver
(Commercial Applications), Exit Loop Detector, Keypads,
7-Day Timer.
Note: Will not override a double entrapment (signalled by
the gate stopped and entrapment alarm on).
Terminals 8 & 5 - Interrupt (Safety) Loop Input
These terminals are intended for use with a loop detector.
This input functions to reverse a closing gate to the open
limit. Latching this input will reset the timer to close.
ONE BUTTON WIRING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SHADOW LOOP INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SOFT OPEN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
INTERRUPT (SAFETY) LOOP INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GL BOARD
J1 TERMINAL BLOCK
24VAC Accessory Power-
Can be found at terminals R1 & R2 located on radio
terminal block.
R2
R1
R4
R3
24 VAC