1 main terminal description – Controlled Products Systems Group 9050-080 User Manual
Page 30

9050-065-M-3-11
28
DANGER
HIGH VOLTAGE!
5.1 Main Terminal Description
Low Voltage Common
Dry Relay Contact
Earth Ground
Circuit Board Power
Circuit Board Power
Motor
Motor
Built-In Solenoid
Lock Power
Full Open
Dry Relay Contact
Standard Reverse
•
When gate is closed, this input will open gate to full position.
•
When gate is open and auto close timer Switch 2
is
turned
ON, input will re-set and hold timer.
•
When gate is open and auto close timer Switch 2
is
turned
OFF, input will close gate.
•
When gate is closing, input will reverse gate.
•
When gate is open and auto close
timer Switch 2 is turned ON, input
will re-set and hold timer.
•
When gate is open and auto close
timer Switch 2 is turned OFF, input
will prevent gate from closing.
•
When gate is closing, input will reverse gate.
•
This input ONLY functions when gate is fully
open or in the closing cycle.
•
Operation of relay is dependent on setting of switch 3.
•
When Switch 3 is turned ON, relay activates
when gate is in the full open position.
•
When Switch 3 is turned OFF, relay is
activated when gate IS NOT closed.
Relay contacts can be set for Normally Open (NO) or
Normally Closed (NC) operation.
Contact rating is 1 amp maximum at 24-volts DC.
8
NC
NO
4702-010
12
11
10
9
8
7
66
5
4
3
2
1
9
10
11
NC
NO
SECTION 5 - MAIN TERMINAL WIRING
24 VAC - 250 mamp. max.
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8