5.1 Main Terminal Description

Low Voltage Common

Dry Relay Contact

Earth Ground

Circuit Board Power

Circuit Board Power

Motor

Motor

Built-In Solenoid

Lock Power

Full Open

Dry Relay Contact

Standard Reverse

When gate is closed, this input will open gate to full position.

When gate is open and auto close timer Switch 2

is

turned

ON, input will re-set and hold timer.

When gate is open and auto close timer Switch 2

is

turned

OFF, input will close gate.

When gate is closing, input will reverse gate.

When gate is open and auto close

timer Switch 2 is turned ON, input
will re-set and hold timer.

When gate is open and auto close

timer Switch 2 is turned OFF, input
will prevent gate from closing.

When gate is closing, input will reverse gate.

This input ONLY functions when gate is fully

open or in the closing cycle.

Operation of relay is dependent on setting of switch 3.

When Switch 3 is turned ON, relay activates

when gate is in the full open position.

When Switch 3 is turned OFF, relay is

activated when gate IS NOT closed.

Relay contacts can be set for Normally Open (NO) or
Normally Closed (NC) operation.

Contact rating is 1 amp maximum at 24-volts DC.

8

NC
NO

4702-010

12

11

10

9

8

7

66

5

4

3

2

1

9

10

11

NC

NO

SECTION 5 - MAIN TERMINAL WIRING

24 VAC - 250 mamp. max.

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8