beautypg.com

Post mount with conduit pad mount with conduit – Controlled Products Systems Group 9050-080 User Manual

Page 18

background image

9050-065-M-3-11

16

4”

11”

Solenoid

Lock

Conduit Area

2.5”

Electronic Box

1.6 Pad, Post or Ceiling Mount without/with J-Box Setup

Post Mount with Conduit

Pad Mount with Conduit

15”

Min.

21” Min.

Concrete Pad

Center

Concrete Pad

Concrete Foundation

Conduit

Concrete Foundation

1” minimum from operator housing to gate.

4” min. above ground.

4” min. above ground.

1” minimum from operator housing to gate.

Underground depth of the

concrete pad is determined

by soil conditions and local

building codes. Reinforced

concrete recommended.

Underground depth of the

concrete foundation is

determined by soil

conditions and local

building codes. Reinforced

concrete recommended.

Concrete pad
MUST be level.

Base Plate
MUST be level.

Operator MUST
be level.

Conduit

area

inside

post.

Conduit

area

inside

post.

Pad, Post or Ceiling Mount Connected with Junction Boxes

All wire connections

can be made on

either side of the

operator housing after

it has been installed.

Never run high
voltage and low
voltage in the
same conduit.

Conduit Knock-Out Sizes

Low
Volt

High

Volt

1/2 1/2

3/4

1/2

Fail-Secure
Key Lock

1/2

3/4

1/2

Note: Weld the posts to the base plate and mount
assembly into concrete BEFORE attaching the
operator. Conduit runs up through 4 x 4 steel posts.

Note: Operator must be mounted
1” min. away from gate.

Low
Volt

High

Volt

WARNING

MOVING GATE CAN CAUSE

Operate gate only when gate area is in sight
and free of people and obstructions.

Do not allow children to play in gate area
or operate gate.

Do not stand in gate path or walk through
path while gate is moving.

Read owner’s manual and safety instructions.

SERIOUS INJURY OR DEATH

CLASS

CERTIFIED TO

CAN/CSA C22.2 NO. 247

CONFORMS TO

ANSI/UL-325

VEHICULAR GATE OPERATOR

HP

53382

MODEL

SERIAL

VOLTS PHASE

AMPS 60

Hz

MAX GATE LOAD

DoorKing, Inc., Inglewood, CA

Conduit Conduit

Base Plate

P/N 2600-418

Pad, post or
ceiling mount

Conduit

12”

Min.

21”

Min.