beautypg.com

Controlled Products Systems Group 9050-080 User Manual

Page 26

background image

9050-065-M-3-11

24

NC
NO

SELF

TEST

TIME

DELAY

REV

SENS

REVERSE LOOP

EXIT LOOP

1

ON

2

3

4

5

6

7

8

12

11

10

9

8

7

6

5

4

3

2

1

47

0

2

-0

10

WA

RNING

MOV

ING

GA

TE C

AN

CA

US

E

Op

era

te g

ate

on

ly w

hen

ga

te a

rea

is

in

sig

ht

and

fre

e o

f pe

ople

an

d o

bstr

uctio

ns.

Do

no

t all

ow

ch

ild

ren

to p

lay

in g

ate

are

a

or o

per

ate

ga

te.

Do

no

t sta

nd in

ga

te p

ath

or

wa

lk th

rou

gh

path

w

hile

ga

te is

mo

vin

g.

Rea

d o

wn

er’s

m

anu

al a

nd s

afe

ty in

stru

ctio

ns.

SE

RIO

US IN

JU

RY

OR

D

EAT

H

CL

ASS

CE

RT

IFIE

D T

O

CAN/CSA

C2

2.2

NO.

247

CONF

ORM

S

TO

ANSI/UL

-3

25

VE

HI

CU

LA

R G

ATE

OP

ERA

TO

R

HP

533

82

MODE

L

SE

RI

AL

VOL

TS

PHASE

AM

PS

60 Hz

MAX

GA

TE L

OAD

Doo

rKin

g, In

c., In

gle

wo

od,

CA

Note: The 6-pin terminal can be unplugged
from circuit board for easy wire connections.

All inputs are normally open (NO).

6-Pin UL 325 Terminal

Secondary Entrapment Protection Device Connection

115 VAC Convenience

Outlets

Secondary Entrapment Protection Devices:

In addition to the inherent reversing sensor system, the Model 9050 has a 6-pin UL 325 terminal for the connection of photo sensors-Type B1
and reversing edges-Type B2 secondary entrapment protection devices required by UL 325 standards. Entrapment protection devices must
be installed
to reduce the risk of injury. Install these devices where the risk of entrapment or obstruction exists while the gate is moving.
The Model 9050 offers numerous options to meet your specific needs. The next 2 pages show wiring and typical positioning of the entrapment
protection devices but specific installations will vary.

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION

4.1 UL 325 Terminal Description

1
2
3
4
5
6

Closed Gate

Wall / Fence

Opening-Direction Photo Beam

Wall / Fence

Filler Post if necessary

Gate Support Post if Installed

Closed Gate

Wall / Fence

Closing-Direction Photo Beam

Closed Gate

Wall / Fence

CLOSE Entrapment Sensor (Photo Sensor):

Obstructed

closing-direction photo beam will stop the gate during the
closing-direction only.
Gate will resume the close cycle
when the obstructed photo beam has been cleared.

Closed Gate

Low Voltage Common:

Common terminals for all the secondary entrapment protection device inputs.

CLOSE Contact Sensor (Reversing Edge):

Obstructed closing-direction reversing edge will stop, then reverse the gate to the open position, during the

closing-direction only.

After the gate reverses to the open position, the timer will

automatically close the gate (if it is turned on). If the
closing-direction reverse edge is activated a second time prior to the gate reaching the
close position, the operator will stop and enter a soft shutdown condition (See page 32).

When the closing-direction reversing edge gets obstructed and the gate is traveling back to the open

position and the opening-direction revering edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 32).

1

2

3

4

5

&

6

OPEN Entrapment Sensor (Photo Sensor):

Obstructed

opening-direction photo beam will stop the gate during the
opening-direction only.
Gate will resume the open cycle
when the obstructed photo beam has been cleared.

OPEN Contact Sensor (Reversing Edge(s)):

Obstructed opening-direction reversing edge(s) will stop, then reverse the gate to the close position during the

opening-direction only.

After the gate reverses to the full close position, any

opening input will cycle the gate again. Note: If the gate is
opening by a time clock and an opening-direction reversing
edge gets obstructed, the gate will return to the closed
position and another input (automatic exit loop, reverse loop. etc.) is needed to cycle the gate open
again.

When the opening-direction reversing edge(s) gets obstructed and the gate is traveling back to the close position and

the

closing-direction reversing edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 32).

Opening-Direction Reversing Edges

Closing-Direction Reverse Edge

Entrapment Area

Entrapment Area

Entrapment Area

Entrapment Area