Controlled Products Systems Group 6400-080 User Manual
Page 16
6400-065-E-05-07
16 6400
installation
guide
8 9
0HOTO
0HOTO
/PEN
#OMMON
#LOSE
#OMMON
3
electrical installation / entrapment protection wiring
The swing gate operator uses
an inherent entrapment sensing
system (Type A) and comes
equipped ready to connect a secondary
entrapment protection device. Entrapment
protection devices are required to reduce
the risk of injury. Install sensors where the
risk of entrapment or obstruction exists
while gate/barrier is moving.
UL INPUTS
1 PHOTO OPEN
If the open photo-beam is activated during the opening cycle, the
gate will stop. The gate will remain stopped until the photo-beam
input is cleared, at which time the gate will resume the open cycle.
2 PHOTO CLOSE
If the close photo-beam input is activated during the closing cycle,
the gate will stop. The gate will remain stopped until the photo-
beam input is cleared, at which time the gate will resume the close
cycle.
3 OPEN EDGE
4 CLOSE EDGE
5 COMMON: terminal for the secondary entrapment protection
device inputs.
6 COMMON
3
Route and connect the PHOTO
OPEN cable to the UL INPUTS
as shown.
2
Route and connect the STAN-
DARD REVERSE cable to the
main terminal strip as shown.
1
Disconnect power to the gate
operator before installing the
sensors.
3
2
2
3