beautypg.com

Controlled Products Systems Group 6400-080 User Manual

Page 16

background image

6400-065-E-05-07

16 6400

installation

guide

8 9

0HOTO

0HOTO

/PEN

#OMMON

#LOSE

#OMMON

3

electrical installation / entrapment protection wiring

The swing gate operator uses
an inherent entrapment sensing
system (Type A) and comes

equipped ready to connect a secondary
entrapment protection device. Entrapment
protection devices are required to reduce
the risk of injury. Install sensors where the
risk of entrapment or obstruction exists
while gate/barrier is moving.

UL INPUTS

1 PHOTO OPEN

If the open photo-beam is activated during the opening cycle, the

gate will stop. The gate will remain stopped until the photo-beam

input is cleared, at which time the gate will resume the open cycle.

2 PHOTO CLOSE

If the close photo-beam input is activated during the closing cycle,

the gate will stop. The gate will remain stopped until the photo-

beam input is cleared, at which time the gate will resume the close

cycle.

3 OPEN EDGE
4 CLOSE EDGE

5 COMMON: terminal for the secondary entrapment protection

device inputs.

6 COMMON

3

Route and connect the PHOTO

OPEN cable to the UL INPUTS

as shown.

2

Route and connect the STAN-

DARD REVERSE cable to the

main terminal strip as shown.

1

Disconnect power to the gate
operator before installing the
sensors.

3

2

2

3