beautypg.com

6 high voltage wiring and battery connection, Danger, Control box must be properly grounded – Controlled Products Systems Group 6002-080 User Manual

Page 21: Caution, Chassis ground

background image

19

2.6 High Voltage Wiring and Battery Connection

Connect 115 VAC input
power wires (black and
white) to black and
white transformer wires.
Connect input green
wire to chassis ground.

Note: To turn-off ALL power to the operator, the AC
power switch must be turned off and the battery
plug must be disconnected from the circuit board.

After power has been

connected, activate the

actuator arm by pressing

the key switch button.

1

2

3

4

5

6

7 8

9 10 11 12 13 14 15 16 17 18 19 20

RED 24V RED

BLK 115V WHT

Chassis

Ground

Alarm

Reset

Reset Button

It is recommended that a surge suppressor be installed on the high voltage power lines.

DANGER

HIGH VOLTAGE!

CAUTION

Do not connect the battery to
the circuit board until power is
needed to test the actuator arm.

1

7

6

5

4

3

2

CONTROL BOX MUST BE PROPERLY GROUNDED!!

4302

Power

Power

Switch

Switch

AC

AC

12 V

o

lt 3 Amp/Hr Batter

y

12 V

o

lt 3 Amp/Hr Batter

y

6002-065-M-6-08