3.1 Circuit Board Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
•
Auto close timer (when
turned on) SW 1, switch 2.
Adjust from 1 second (full
counter clockwise) to
approximately 23 seconds
(full clockwise).
•
Self test (when turned
on) SW 2, switch 1.
CAUTION
Do not run self-test with the
operator connected to the gate.
The drive chain must be discon-
nected from the operator to run
the self-test. This feature is
designed for bench testing ONLY.
•
Dry relay contacts
(terminals 12-13) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on
the N.O. or N.C. pins
respectively.
•
Set the DIP-switches on the
circuit board to the desired
setting. See switch-setting
charts on next page.
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
N.O.
N.
C.
SW 1
SW 1
1
ON
2
3
4
SW 2
1
ON
2
3
4
SW 2
Loop Detector
1
23
EXIT
REVERSE
9410
Loop Detector
9410
Auto Close Timer
Self Test
DIP-Switches
Dry Relay Contact
•
Adjust reversing sensitivity
for OPEN and CLOSE directions.
Min
Max
OPEN
CLOSE
Min
Max
Reverse Sensors