Table 3-24 Entering Alarms Control Parameters
CP
Parameter Name
Parameter Value
Enter the RPMs at or below which you want 
the Alarm output to activate.
This Control Parameter determines the 
circumstances under which the ML–Drive 
will alert you to potential operating problems.
The alarm can be wired to activate a 
warning light, a warning sound, or to shut 
down the system under specified 
conditions. Alarm Format (CP-10) 
determines which alarm conditions will 
activate the Alarm output, using the values 
that are entered in Low Alarm (CP-12), 
High Alarm (CP-13), Ramped Error Alarm
(CP-14) and Scaled Error Alarm (CP-15). 
CP-10
Alarm Format
CP-12
Low Alarm
CP-13
High Alarm
CP-14
Ramped Error Alarm
CP-15
Scaled Error Alarm
Enter the RPMs at or above which you want 
the Alarm output to activate.
Enter the RPM Deviation between the 
Ramped Reference and the feedback that will 
activate the Alarm output.
Enter the RPM Deviation between the Scaled
Reference and the feedback that will activate 
the Alarm output.