CONTREX ML-Drive User Manual
Page 126

Glossary - 6
Input Monitoring
Lead Frequency (MP-41)
Feedback Frequency (MP-43)
Logic Inputs, Group A (MP-54)
Logic Inputs, Group B (MP-55)
Input Test
Tests the Logic Inputs.
Inputs
AC Power (J2 pins 3, 4, 5)
I/O Power (J4 pins 1,2)
Lead Frequency (J4 pins 3, 5)
Feedback Frequency (J4 pins 4,5)
Run (J4 pins 6, 8)
Jog (J4 pins 7, 8)
R–Stop (J4 pins 9, 11)
F-Stop (J4 pins 10, 11)
Master or Follower (J4 pins 12, 14)
Setpoint Select (J4 pins 13, 14)
Integral
See Appendix C;CP-66.
Jog
One of four operating states. Jog increases the RPMs at
the acceleration rate that is specified in Acceleration Time
(CP-16) until the Jog Setpoint (CP-05) is achieved. When
Jog is terminated, there is no Deceleration Time; the drive
motor comes to an immediate stop.
Keypad Test
Tests the Keypad.
LED Display
The two digit Parameter Code is displayed on the left LED
Display. The Parameter Code's value is displayed on the
right LED display. This value can be up to four digits.
Logic Inputs
F–Stop
R–Stop
Run
Jog
Setpoint Select
Master/Follower