Appendix d: control parameter reference – CONTREX ML-Drive User Manual
Page 151
![background image](/manuals/334452/151/background.png)
D - 1
USER
CODE DESCRIPTION
MIN
MAX DEFAULT
RECORD
UNITS
CP-01
Master Setpoint 1
0000
9999
0000
ENG
CP-02
Master Setpoint 2
0000
9999
0000
ENG
CP-03
Follower Setpoint 1
0000
9999
0000
ENG
CP-04
Follower Setpoint 2
0000
9999
0000
ENG
CP-05
Jog Setpoint
0000
9999
50
RPM
CP-06
Direct Setpoint
0
+100
0
%
CP-10
Alarm Format
0
15
15
CODED
CP-12
Low Alarm
0000
9999
0000
RPM
CP-13
High Alarm
0000
9999
2000
RPM
CP-14
Ramped Error Alarm
0000
9999
2000
RPM
CP-15
Scaled Error Alarm
0000
9999
2000
RPM
CP-16
Acceleration Time
000.0
600.0
5.0
SEC
CP-17
Deceleration Time
000.0
600.0
5.0
SEC
CP-20
Master Eng. Units
0.000
9999
2000
ENG
CP-21
Follower Eng. Units
0.000
9999
1.000
ENG
CP-30
PPR Lead
1
9999
60
PPR
CP-31
PPR Feedback
1
9999
60
PPR
CP-33
Max RPM Lead
1
9999
2000
RPM
CP-34
Max RPM Feedback
1
9999
2000
RPM
CP-61
Direct Enable
0
1
0
CODED
CP-62
Inverse Scaling
1
2
1
CODED
CP-64
Display Mode Follower
1
2
2
CODED
CP-65
Gain
0
9999
5000
—
CP-66
Integral
0
9999
2000
—
CP-67
Derivative
0
9999
9000
—
CP-68
Feedforward
500
2000
1000
DAC bit
CP-70
Device Address
1
32
1
—
CP-71
Baud Rate
1
6
6
CODED
CP-72
Character Format
1
3
2
CODED
CP-73
Control Mask
0
3
0
CODED
CP-74
Drive Enable Logic
0
1
0
CODED
CP-80
RMS Current Limit
4.0
10.0
10.0
AMPS
CP-81
Peak Current Limit
4.0
15.0
10.0
AMPS
CP-98
Keypad Lockout
1
9999
0
CODED
APPENDIX D: CONTROL PARAMETER