Ac power, Lead frequency – CONTREX ML-Drive User Manual
Page 22

2 - 8
AC Power
(J2 pins 3, 4, 5)
The ML–Drive model #3200-1933
operates on 115 VAC + 15%, 0.1
Amp., 50/60 Hz. The ML–Drive model
#3200-1934 operates on 230 VAC +
15%, 0.1 Amp., 50/60 Hz.
* Fuse L1 for 115VAC applications.
Fuse L1 and L2 for 230VAC
applications. Use 15 AMP 250V
normal blow fuses.
Lead Frequency
(J4 pins 3, 5)
The Lead Frequency is a pulse train
input that the ML-Drive uses to
determine the speed of the lead
motor. For signal level specifications,
refer to
References: Appendix A
,
ML-Drive Specifications,
page A-1
Figure 2-5 Input Power
Figure 2-6 Lead Frequency
Signal
Common
3
5
J4
L1
Neutral or L2
GND/PE
1
2
3
J3
*
*