Specifications

Sensor

Sample temperature

Measurement from -5 to 50°C (23 to 122°F)
Sensor resistant to temperature from -5 to 100°C (23 to 212°F)

Sample pressure

1 to 20 bar absolute (14.5 to 290 psia)

Sample flow rate requirement

50 to 300 mL/min

Sample types

K1100 sensor

Water only

M1100 sensor (low range)

Water and beer

M1100 sensor (high range)

Water, beer, wine, wort and carbonated drinks

CIP

K1100 sensor

Not designed for use in CIP processes

M1100 sensor

Resistant to all common CIP methods

Measurement range

Low range sensors: 0 to 2,000 ppb (dissolved)
High range sensors: 0 to 40 ppm (dissolved)

Repeatability

Low range sensors: ± 0.4 ppb or 1%, whichever is the greater
High range sensors: ± 0.015 ppm or ± 2% whichever is the greater

Reproducibility

Low range sensors: ± 0.8 ppb or 2%, whichever is the greater
High range sensors: ± 0.02 ppm or ± 3% whichever is the greater

Accuracy

Low range sensors: ± 0.8 ppb or 2%, whichever is the greater
High range sensors: ± 0.02 ppm or ± 3% whichever is the greater

Limit of detection (LOD)

Low range sensors: 0.6 ppb
High range sensors: 0.015 ppm

Response time (90%)

Low range sensors: < 10 seconds in gas phase; < 30 seconds in liquid phase
High range sensors: < 10 seconds in gas phase; < 50 seconds in liquid phase

Warm-up time

None

Display resolution

0.1 ppb

Calibration

Low range sensors: Single point calibration (zero)
High range sensors: Two at cap replacement (zero and air), one during use (air)

Calibration sample

Low range sensors: Standard 99.999% N

2

(quality 50) or equivalent oxygen free gas

High range sensors: Standard 99.999% N

2

(quality 30) or equivalent oxygen free gas, air

Accessories

Accessories

Active spots, spare sensors, tool kit, portable calibration setup, etc.
Ask your local Hach Lange representative for more details on all available spare parts and
accessories.

Installation

In process sensor installation
devices

ORBISPHERE insertion/extraction valve for installation on Varinline® access units
ORBISPHERE 28 mm sensor weld-on socket
PG 13.5 stationary housing for installation on Varinline® access units
Note:

This device is only available for the M1100 sensor

28 mm stationary housing for installation on Varinline® access units

Ambient temperature

-5 to 50 °C (23 to 122 °F)

Humidity

0 to 95% non-condensing relative humidity

Power supply

Universal 85-264 VAC @ 50/60 Hz, 25 VA
10-36 VDC, 25 W

Weights

Wall (pipe) mount controller

3.8 kg

Panel mount controller

2.9 kg

M1100 12 mm (PG 13.5) sensor

0.6 kg

K1100 and M1100 28 mm sensor

0.74 kg

Calibration device

0.7 kg