beautypg.com

Global Specialties PB-507 - Manual User Manual

Page 29

background image

29

The following settings are saved:

Function generator: frequency, level, waveform, output On/Off, TTL On/Off

Pulse generator: frequency, level, duty cycle, CMOS On/Off, TTL On/Off

Frequency counter: input signal type

DC power supplies: positive voltage, negative voltage

Logic switches: state, TTL/CMOS

SPDT switches state

Logic indicator: TTL/CMOS

Logic probe: TTL/CMOS, PLS/MEM

7.2.2 State name

You can assign a custom name to each of the ten storage locations. The name
can contain up to 15 characters. You can assign the same custom name to
different storage locations.

To assign a name to the selected location select the Enter name option. The
following screen will appear:

Figure 16


Use the arrow soft keys to select a character in the name box (“1: No name”).

Press the “Set” soft key to insert a character in the name box. Use the arrow
keys to move the selection.
Use the “CAPS” option to switch between upper-case and lower-case.
Use the “ “ option to delete a character in the name box.

To enter the desired character, press the “OK” soft key.

When the state name is specified, move the cursor to the number of the state (1
in this case) and press “Back” to go back to the Store state menu.

The name entered for the selected state will be saved only when you save the
state in memory by selecting the Store state option.