beautypg.com

English, Remove the blanking strips covering the screws, Fig. 15: installation of a wall-mounted version – Burkert Type 8025 User Manual

Page 26: Wire acc. to the instructions in chap. "8, 106 mm

background image

26

Installation

Type 8025 / 8035

7.4.

installation of a wall-mounted version of the 8025 transmitter

note

risk of material damage if the cable glands are not tightly screwed on the housing
• Before installing the wall-mounted housing on its support, tighten the nuts of the entry item of the cables glands at a

torque of 1.5 Nm.

The flow transmitter in a wall-mounted version has 4 holes in the bottom of the housing.

Remove the blanking strips covering the screws.

Blanking strips

ENTER

0....9

FLOW

Nut of the entry item

Loosen the 4 screws and open the cover to get access to the holes [1].

1

1

1

1

230V

L N

230V

T 250 mA

5 6 7 8 9 10

L N

NPN SENSOR
1 PULSE INPUT

2 -

3 +

4 NC

SUPPLY

1

2

3

4 PE

3A/230VAC

REL1

REL2

FLOW SENSOR

FLOW SENSOR

COIL

NPN

CURRENT

SOURCE SINK

COIL SENSOR
1

2

3 NC

4 NC

L+

L-

PE

P-

P+

NC

L+

L-

PE

P-

P+

Iout

PULSE

OUTPUT

Without

With

Relays

Supply

12..36Vdc

106 mm

106 mm

Fig. 15: Installation of a wall-mounted version

Secure the housing to the support respecting the dimensions indicated in "Fig. 15".

Wire acc. to the instructions in chap. "8".

Close the housing and tighten the 4 screws of the cover.

English

This manual is related to the following products: