Burkert Type 8025 User Manual
Operating instructions
This manual is related to the following products:
Table of contents
Document Outline
- Types 8025 / 8035
- MA8025_8035_Flowmeter_EN_1
- 1. About this manual
- 2. Intended use
- 3. Basic safety information
- 4. General information
- 5. Description
- 5.1. Area of application
- 5.2. General description
- 5.3. Measuring principle
- 5.4. Available versions of the 8025 compact flowmeter
- 5.5. Available versions of the 8025 panel-mounted transmitter
- 5.6. Available versions of the 8025 wall-mounted transmitter
- 5.7. Available versions of the SE35 electronic module
- 5.8. Description of the name plate
- 6. Technical data
- 7. Installation
- 8. Wiring
- 8.1. Making the installation equipotential
- 8.2. Wiring the 8025 compact version and the 8035 with a 4 pin male fixed connector
- 8.3. Configuring the selectors
- 8.4. Wiring the 8025 in a compact version and the 8035, with or without relays, with cable glands
- 8.4.1. Wiring instructions
- 8.4.2. Wiring of the relays (versions with relay output)
- 8.4.3. Wiring the 8025 compact version and the 8035, 12-36 V DC, without relays, with cable glands
- 8.4.4. Wiring the 8025 compact version and the 8035, 12-36 V DC, with relays, with cable glands
- 8.4.5. Wiring the 8025 compact version and the 8035, 115/230 V AC, without relays, with cable glands
- 8.4.6. Wiring the 8025 compact version and the 8035, 115/230 V AC, with relays, with cable glands
- 8.5. Connecting the flow sensor to the 8025 transmitter, panel-mounted version or wall-mounted version
- 8.6. Wiring the 8025 remote (wall-mounted or panel), 12-36 V DC, with or without relays
- 8.7. Wiring the 8025, wall-mounted version, 115/230 V AC, with or without relays
- 9. operating and commissioning
- 9.1. Safety instructions
- 9.2. Operating levels of the device
- 9.3. Description of the navigation keys and the status LEDs
- 9.4. Using the navigation keys
- 9.5. Details of the Process level
- 9.6. Details of the Parameters menu
- 9.6.1. Choosing the display language
- 9.6.2. Choosing the flow rate units, the number of decimals and the units of the totalizers
- 9.6.3. Entering the K factor of the fitting used
- 9.6.4. Configuring the current output
- 9.6.5. Configuring the pulse output
- 9.6.6. Configuring the relays
- 9.6.7. Configuring the filter of the measured flow rate
- 9.6.8. Resetting both totalizers
- 9.7. Details of the Test menu
- 10. Maintenance and troubleshooting
- 11. Spare parts and accessories
- 12. Packaging, Transport
- 13. Storage
- 14. Disposal of the product