Structureandfunctionofthemodules

Valves

Operating principle

Operation

Width

type

3/2-way

C (NC)

Internal control air

16

6526

D (NO)

C (NC)

Control assist air

(External)

D (NO)

C - vacuum (NC)

5/2-way

H

Internal control air

10

6525

Control assist air

(External)

Internal control air

16

6527

Control assist air

(External)

5/3-way

L Lock middle

position

Internal control air

10

0460

N Deaerated

L Lock middle

position

16

0461

N Deaerated

5/2-way impulse

H

Internal control air

10

0460

16

0461

NoTE!

Valves with control assist air

If valves are used with control assist air, the exhaust air escapes from the pilot valve into the environment. Valves
with control assist air cannot be combined on the valve cluster with valves with internal control air, as the con-
nection X (see Chapter “7.2. Connection modules”) is used differently.

Valves 6524 and 6525 (Exception: Type 6524 2 x 3/2-way)

The assembly of the valve cluster Type 8644 with the valves 6524 and 6525 is authorized for use in Zone 2

in accordance with II 3 G Ex nA II T4 with the number PTB 02 ATEX 2048.

Restrictions for use in Zone 2

CAuTIoN!

For valve types 6526 and 6527 the valve switch-off time restriction T

OFF

≥ 0.2 s must be observed for use in

Zone 2 with temperature class T4 under the following conditions:

• at quick switch-on cycles (valve switch-on time T

ON

< 3 s)

• maximum ambient temperature of +55° C

• maximum permitted overvoltage of U

Nominal

+ 10 %