beautypg.com

Pneumatic base module with integrated p shut-off – Burkert Type 8644 User Manual

Page 48

background image

48

Structureandfunctionofthemodules

non-return valve for the vent connections

As certain applications require a functionality with non-return valves, there are also appropriate types for this purpose:

• Without non-return valve,

• Non-return valve in R,

• Non-return valve in R+S,

• An integrated P shut-off is also available for the modules MP11 (2-fold mono and 8-fold mono).

mp11

mp12

D6

D8

D4

G 1/8"

D 1/4"

NPT 1/8"

M5

D6*

M7

M5*

-

M7*

-

D4*

-

D 1/4"*

* Special design 3-fold module with 10 mm valves

7.4.2.

pneumatic base module with integrated p shut-off

general description

The P shut-off can be integrated in the module for the pneumatic base modules MP11, 2-fold and 8-fold versions.
This option allows a defective valve to be changed under pressure without having to depressurize the complete
valve cluster or system. When the valve is changed by a mechanism, the open cross section is reduced until only
a slight residual leakage occurs.
features and restrictions

If the P shut-off is used, there are some restrictions with respect to the operating data of the complete system:

The flow rate of the valves Type 6524 / 6525 is reduced to approx. 60%*.

The operating pressure range must be between 5 and 7 bar if the P shut-off is used, otherwise there may be
problems with the P shut-off.

As the pressure supply for the pilot valves is not shut off if valves are used with external control assist air, the P
shut-off can be used only in conjunction with the valves with internal control air within the restricted pressure range.

The P shut-off can be combined with the integrated non-return valves.

NoTE!

If using the P shut-off base modules, ensure that the pressure supply of the valve clusters is designed with a cor-
respondingly large volume (minimum hose diameter 8/6 mm).

* Mean value from measurements