Burkert Type 8644 User Manual
Page 28
28
Structureandfunctionofthemodules
On the electronic base module the digital outputs are switched where the valves are located. Depending on the
operating principle of the valve, these outputs switch the internal P channel to the working connections (outputs)
of the pneumatic base modules.
NoTE!
• Do not change attached valves until AirLINE has been depressurized.
• If a P shut-off is used, the valves can also be changed under pressure.
Variants
Thanks to the modular design of the valve disc, there are several variants:
types
pneumatic/electronic
mp11 / me02
mp12 / me03
Add-on dimension
11 mm
16.5 mm
Valve types
6524
6524 (2x3/2-way)
6525
0460
6526
6527
0461
Number of valve locations on
electronic base module
2-fold
4-fold
2-fold
3-fold*
4-fold
Number of valve locations on
pneumatic base module
2-fold
8-fold
2-fold
3-fold*
4-fold
Connection version
(Pneumatic base module)
D6
D4
D1/4"
M5
M7
D8
G1/8"
NPT 1/8"
D4**
D1/4**
D6**
M5**
M7**
Non-return valves (optional)
without non-return valve
non-return valve in R channel
non-return valve in R+S channel
P shut-off (optional)
with P shut-off***
not available
* Overall width of electronic/pneumatic base module = 33 mm, with 3 slots for 10 mm valves
** Special design 3-fold, 10 mm valves 6524 / 6525
*** Available for certain valve types and with function restriction only. See also “6.3. Technical Data of the valve
block” and “7.4. Pneumatic base module”
english