beautypg.com

Technical data, Operating conditions, Technical data of the entire system – Burkert Type 8644 User Manual

Page 16

background image

16

TechnicalData

6.

Technical daTa

6.1.

Operating conditions

WArNINg!

risk of injury!

Malfunction if used outside!

• Do not use Type 8644 AirLINE system outdoors and avoid heat sources which may cause the permitted tem-

perature range to be exceeded.

permitted temperatures

Storage temperature:

-20 ... +60 °C

Permitted air humidity:

75% on average, 85% occasionally

Permitted air pressure

Operation:

80 kPa to 106 kPa (up to 2,000 m above sea level)

Storage / transport:

70 kPa to 106 kPa (up to 3,000 m above sea level)

Protection class:

Class 3 in accordance with VDE 106, IEC 60536

Protection class:

IP20 in accordance with IEC 60529

6.2.

Technical data of the entire system

electrical power supply

Nominal voltage

24 V / DC

Tolerance

-15 % / +20 %

Valve types: 0460, 0461

-10 % / +10 %

Valve type: 6524 (2 x 3/2-way)

-15 % / +10 %

current carrying capacity

Valve block (via connection module on left):

max. 2.5 A

Valve type

Valve flow

before power reduction

after power reduction

6524

43 mA

28 mA

6524 (2 x 3/2-way)

43 mA

18 mA

6525

43 mA

28 mA

6526 (1W / 2 W)

42 / 85 mA

33 / 52 mA

6527 (1W / 2 W)

0460

41 mA

-

0461

41 mA

-

english

Type 8644